Product Entity

SR-FG-01 Frameless Glass Railing System

SR-FG-01 is Sun Railings factory-fabricated commercial railing product line — drawing-based BOQ, IS structural coordination, NBC 2016 guard compliance and PMC submittal support from Jeedimetla, Hyderabad since 1998.

Related systems: SR-GR-01 glass railing systems Hyderabad · SR-SG-01 SS balustrade glass infill systems · SR-AL-01 aluminium glass railing alternative · SR-SS-01 stainless steel railing packages

Download specification support: Fabrication capabilities & BOQ specification sheet · Request SR-FG-01 BOQ proposal

Commercial Applications

SR-FG-01 Frameless Glass Railing System — Commercial Applications

  • Commercial towers & IT parks — podium, atrium and terrace guards with consultant BOQ alignment.
  • Residential builders — phased balcony and corridor railing for multi-tower Hyderabad programmes.
  • Hotels & hospitality — lobby, pool deck and circulation balustrades per NBC 2016.
  • Institutional campuses — staircase, ramp and elevated walkway guards with IS 875 load coordination.
  • Healthcare & metro — durable guard systems for high-traffic public circulation zones.
Frameless glass railing manufacturers Hyderabad – frameless glass railing system
Home / Products / Frameless Glass Railing

IS 2553 – Toughened Glass – SS316

Frameless Glass Railing Systems | Hyderabad

Frameless glass railing Hyderabad systems for commercial atriums, mall concourses, SEZ campuses and high-rise podium edges. IS 2553 toughened glass with patch fitting, spider fitting and channel base options. Fabricated at Jeedimetla. Also see: SS Glass Railing | Balcony Railing

IS 2553 GlassSS316 FittingsSpigot MountBase Channel12mm ToughenedNo visible balustrades
IS 2553Toughened safety glass specification for all frameless systems
12-15mmToughened glass thickness options for balcony and staircase
SS316Marine grade fittings for coastal and high-humidity environments
24hrFree site visit and measurement anywhere in Hyderabad
Overview

Frameless Glass Railing Systems for Commercial Projects

A frameless glass railing system uses IS 2553 toughened safety glass panels fixed at the slab edge with no intermediate vertical posts — delivering unobstructed sightlines for commercial atriums, mall voids, airport concourses and high-rise podium decks. Sun Railings manufactures frameless glass railing Hyderabad systems at Jeedimetla for PMC teams, architects and EPC contractors specifying guard systems on institutional and infrastructure projects across Telangana and Andhra Pradesh.

Sun Railings fabricates frameless glass railing systems at our Jeedimetla factory. We use IS 2553-compliant toughened glass in 12mm, 15mm and 17.5mm laminated options with SS316 grade fittings. All systems include structural calculations and IS compliance documentation for building approvals.

Supplied to IT parks, shopping malls, airport terminals, hospital lobbies, SEZ office campuses and high-rise commercial towers across Hyderabad and wider South India. Drawing-based contracts with documented IS compliance and site measurement within 24 hours for consultant submittals.

IS 2553 GlassSS316 Fittings12mm ToughenedStructural CalcsNBC 2016
Frameless glass railing balcony installation Hyderabad by Sun Railings
Frameless glass railing staircase commercial building Hyderabad
Fixing Systems

Patch, Spider and Channel Base Fixings
Spigot-mounted frameless glass panel – point-fix hardware detail, Hyderabad
01

Patch Fitting (Point-Fix)
SS316 Patch Fitting — 10–12mm Toughened Glass
Individual SS316 patch fittings or standoffs fixed through core-drilled glass panels. Minimal visible hardware for feature atrium edges and podium guards where transparency is the design priority on commercial projects.

Zero Visible Frame

Base channel frameless glass – floor-mounted profile detail, Hyderabad
02

Channel Base (U-Profile)
SS316 U-Channel – 12-15mm Glass
Glass panels inserted into continuous SS316 U-channel fixed to floor slab. No drilling through glass. Stronger and faster to install than spigot system.

Structural System

Atrium frameless glass balustrade – multi-level interior install, Hyderabad
03

Spider Fitting System
SS316 Spider — Laminated Glass
Multi-arm spider connectors for large-format glass panels on atrium voids, double-height lobbies and airport concourses. Laminated PVB glass for assembly-zone safety and post-breakage retention per consultant specification.

Laminated PVB

Pool deck frameless glass edge railing – wet-area SS316 hardware, Hyderabad
04

High-Rise Podium Edge
12–15mm Glass — Wind Zone Calcs
Frameless glass balustrades for high-rise commercial podium edges, terrace setbacks and rooftop plant decks. Glass thickness confirmed against IS 875 wind and horizontal load calculations for the building height and exposure zone.

Wet Area Rated

Glass Specifications

IS 2553 Toughened Glass for Frameless Systems

All frameless glass railing Hyderabad systems use heat-soaked toughened safety glass conforming to IS 2553. Standard commercial specifications include 10mm toughened glass for low-height guards and internal atrium edges where consultant drawings confirm span and load. 12mm toughened glass is the typical specification for podium balustrades, mall void edges and circulation decks to NBC 2016 guard heights. Laminated combinations — 13.5mm (6+1.52+6) or 17.5mm — are specified where post-breakage retention is mandatory in assembly zones, airports and hospital concourses.

Glass edges are polished and arrised. All panels carry heat-soak test documentation and material test certificates for PMC submittal. Hardware is SS304 for standard commercial environments and SS316 for coastal, humid or high-chloride exposure. Structural calculations reference IS 875 Part 2 horizontal imposed loads and NBC 2016 guard height requirements — issued with shop drawings from Jeedimetla.

Project Types

Where Frameless Glass Railing Is Specified

Shopping Malls and Retail Atriums
Multi-level mall voids, food court edges and escalator landings where unobstructed sightlines and IS-compliant guard heights are required for fire and building authority approvals.

Airports and Metro Concourses
Passenger circulation decks, viewing galleries and platform edges. Laminated glass and documented load calculations for assembly-category imposed loads on infrastructure projects.

SEZ and IT Park Campuses
Office podium edges, terrace setbacks and campus bridge links. Channel base fixing for repeat floor plates and fast installation on phased commercial construction programmes.

Hospitals and Institutions
Atrium voids, ramp guards and lobby mezzanines in AIIMS, hospital and university projects. Documentation packages aligned to consultant review and authority submittal cycles.
Why Frameless vs Framed

Frameless or Framed — Specification Guide

Frameless glass railing systems maximise transparency — no vertical posts interrupt the sightline. They suit atriums, concourses and facade edges where architecture demands clear glass guards. Load is carried through the glass panel and base or point fixing; glass thickness and fixing spacing must be confirmed in structural calculations.

Framed glass railing uses SS304 or SS316 balustrades and handrails with glass infill panels. Posts share imposed loads and simplify maintenance on high-traffic circulation routes, industrial mezzanines and exterior decks with heavy assembly use. Framed systems tolerate wider post spacing and are often specified where future panel replacement must not require slab-edge disruption.

For most commercial atrium and podium applications in Hyderabad, frameless channel base or spider systems are specified for visual clarity; framed systems are retained where the structural engineer requires post-assisted load paths. Sun Railings supplies both — specification follows the approved consultant drawing.

Commercial frameless glass railing atrium installation Hyderabad
Framed SS glass railing commercial building interior Hyderabad

AI Overview · Definition

What Is Frameless Glass Railing? — SR-FG-01 System Definition

Frameless glass railing is a guard system with no visible vertical posts — toughened safety glass (IS 2553) or toughened laminated glass (IS 16613) retained in a continuous base channel, base shoe profile, or SS316 spigot fixing at the slab edge. SR-FG-01 is Sun Railings frameless glass railing product line for atriums, podiums, lobbies, and terrace guards where minimal metal and maximum transparency are specified — fabricated at Jeedimetla with IS 875 load documentation and NBC 2016 guard heights.

Compare: SR-SG-01 SS balustrade-and-glass (visible balustrades) · SR-CG-01 curved glass · SR-GR-01 glass hub.

Specification Matrix

SR-FG-01 Frameless Glass Railing Specification Matrix

Fixing type Glass Hardware Application
Base channel / shoe 12–15 mm toughened SS316 channel Podium, balcony edge
Spigot (point fix) 12–15 mm toughened SS316 spigot Premium lobby, atrium
Laminated public zone 13.5 mm + 1.52 PVB SS316 Hospital, airport circulation
Side-mounted standoff 15 mm typical SS316 standoff Feature stair, hospitality
Comparison

Frameless vs SS Glass Railing — When to Specify SR-FG-01

Criteria SR-FG-01 Frameless SR-SG-01 SS Glass
Visible metal Minimal — channel/spigot only SS balustrades + top rail
Robustness Design-led; torque-critical Higher — post framework
Best for Premium lobbies, podiums Towers, hospitals, stairs
PMC / EPC

Frameless Glass Railing PMC Submittal Pack — SR-FG-01

  1. Base fixing layout — anchor type, edge distance, slab reinforcement coordination.
  2. Glass make-up schedule — IS 2553 / IS 16613, thickness, interlayer.
  3. IS 875 guard load class and deflection criteria on panel height.
  4. SS316 hardware MTCs and torque specification for spigots.
  5. Sealant and drainage detail at base shoe for exterior podiums.

Specifier Guide

Frameless Glass Guard Applications for Architects and PMC Teams

SR-FG-01 frameless systems use toughened glass with base-shoe channels or patch fittings so the guard reads as a glass plane with minimal metal — common on lobbies, podiums, hotel atriums and balcony faces where the elevation treatment is architectural, not industrial. Sun Railings fabricates frameless runs from Jeedimetla with glass schedules tied to IS 875 spans and NBC guard heights on approved details.

  • Double-height lobbies — Base-shoe or patch systems with SS316 hardware at feature entries; often alongside SS glass balustrade on upper levels.
  • Podium and pool decks — Coastal specs push SS316 shoes and laminated make-ups where the consultant requires.
  • Residential feature balconies — Frameless on sell-facing tiers; modular repeating bays on standard floors.
  • Transit and commercial atria — Higher load tiers; coordinated with glass railing programme documentation on mixed-material jobs.
Material Selection

Frameless Hardware and Glass Make-Up Selection

Fixing type Glass Best suited for
SS base shoe (side mount) 12–15 mm toughened Straight podium and balcony runs
Patch fittings 12 mm toughened typical Minimal channel visibility at landings
Laminated make-up Per structural note Coastal, overhead, or consultant-specified safety make-up

Frameless guards demand tighter slab-edge coordination than post-and-rail systems. We issue setting-out drawings before channel order. Where maintenance policy favours visible structure, SS balustrade-and-glass or aluminium shoe systems are noted as alternates on the BOQ.

PMC / EPC

Frameless Railing Submittals — Consultant Review Set

  1. Plan and elevation runs with glass panel IDs and shoe / patch locations.
  2. Structural coordination note for anchor type and slab edge embed / post-installed fixings.
  3. IS 2553 glass specification with heat-soak where required.
  4. IS 875 span and guard load reference per panel width.
  5. Sealant and setting block specification at shoe interfaces.
  6. Crate and panel handling instructions for site teams.

Project portfolio · Fabrication scope · SR-FG-01 BOQ request

Procurement

Frameless Glass — Questions from Developer Procurement

Is frameless always more expensive than balustrade-and-glass?

Unit rates depend on glass area, hardware type and site access. On feature zones the premium is often accepted for elevation quality; on repeating typical floors many developers switch to SR-SG-01 or modular bays.

Who owns the structural check on frameless spans?

The project structural consultant confirms imposed and wind loads; we size glass thickness and fixing centres to the approved calculation, documented on the submittal.

Can frameless guards be used on curved podium edges?

Yes with heat-bent glass scheduled from plan radius. Lead time includes bending; straight frameless and curved lots are separated on the BOQ.

What happens if slab edge level varies on site?

Shoe systems include adjustment within the limits on the shop drawing. Beyond that, a revised detail is issued for consultant approval before glass fabrication.

How do you package frameless with other guard types?

Each system keeps its own drawing register and dispatch lot numbers — frameless lobby, SR-SG-01 typical floors and SS stair handrails are common splits on one project.

Related systems: Glass railings · SS glass balustrade · SS railings · Staircase glass · Aluminium glass · Modular railing

Application Guide

Commercial Application Guide — Frameless and Exterior Glass Railing

Frameless glass railing removes visible vertical metal at the guard line — glass is stabilised by base shoes, point spigots or channel with optional slim top rail. Tempered glass railing and toughened glass railing refer to the same IS 2553 heat-treated make-up; project documents may use either term on the specification.

  • Balcony applications — Tower typical floors with 10–12 mm toughened infill; wind exposure per IS 875 may increase thickness or require post-assisted spans on corner units.
  • Podium applications — Continuous exterior glass railing at retail and hospitality podiums; drainage fall and channel alignment set before anchor drilling.
  • Terrace applications — Roof terraces and amenity decks; laminated glass where consultant schedule mandates residual strength on overhead-adjacent edges.
  • Interior voids — Atria and mezzanines where the architect pairs frameless glass with minimal stainless handrail for code continuity.

Semi-frameless and post-supported options on the same campus are documented on glass railings Hyderabad; channel system glass railing covers full U channel parapet conditions.

Material Matrix

Material Selection Matrix — Frameless Glass Systems

Condition Typical make-up
Inland balcony 12 mm toughened, SS304 spigot or base shoe, NBC 1.0 m guard height.
Coastal exterior glass railing SS316 hardware, laminated glass where salt exposure is on the durability matrix.
Podium parapet U channel or structural glass balustrade; 12–15 mm glass per structural guard sheet.
Stair adjacent Often requires continuous handrail — frameless panel with SS top cap per NBC handrail rules.
Budget-sensitive phase Aluminium profile glass railing on upper residential bands while frameless remains on sell face.
PMC / EPC

PMC Documentation Checklist

  1. Structural and architectural guard details — glass thickness, fixing type, expansion joint treatment.
  2. IS 2553 glass compliance submittal and heat soak statement if specified.
  3. SS grade declaration — SS304 inland, SS316 for listed aggressive zones.
  4. Site inspection log — anchor embed depth, spigot torque, channel level survey.
  5. Handover package — panel numbering, replacement sequence, cleaning and inspection interval for FM.
Consultant Notes

Consultant Specification Notes

Distinguish true frameless (no continuous top rail) from minimal-top-rail systems on the drawing — NBC and local authority reviewers often expect graspable handrail on stair-adjacent runs. State imposed load per IS 875 and whether glass is simply supported or structurally participating. For exterior glass railing, specify drip details, weep holes in shoes, and sealant compatibility with stone or tile podium finishes. Document cleaning access for facade teams — panel removal sequence should appear on the handover sheet, not only in the installer manual.

Procurement

Commercial Buyer Questions — Frameless Glass Railing

Is tempered glass the same as toughened glass on tender documents?

Yes — both refer to heat-treated safety glass under IS 2553; align the BOQ line with the specification term to avoid duplicate items.

What drives cost on podium versus balcony quantities?

Channel length, glass thickness tier, hardware grade and site access for long panel handling — podium runs often use thicker glass and SS316.

Can frameless guards be phased by tower wing?

Yes — shop drawings are issued per wing with frozen panel sizes so repeat floors do not trigger glass re-optimization.

Applications

Commercial Applications for Frameless Glass Railing Systems

Frameless glass railings remove visible vertical posts at the guard line — glass is stabilised by base shoe, spigot or slim channel with optional handrail cap. Sun Railings fabricates frameless glass railing modules at Jeedimetla for commercial railings on towers, hospitality and institutional campuses across Hyderabad and India.

  • High-rise towers — Sell-face balconies and corner units where wind load per IS 875 may step glass thickness on exposed faces.
  • Hotels and commercial complexes — Lobby voids, pool terraces and restaurant decks — laminated glass where consultant schedules require.
  • Hospitals and IT parks — Internal atria and podium edges; coordination with main contractor screed levels before base shoe set-out.
  • Metro stations and airports — Feature balustrades on circulation decks — interface drawings with civil finishes.
  • Educational institutions — Auditorium galleries and external stair guards with NBC 2016 height on sections.

Programme context for mixed systems: glass railings hub, channel system glass railings on parapet zones, stainless steel railings on service terraces.

Material Selection

Glass Railing Material Selection — Frameless Systems

Parameter Guidance
Toughened glass (IS 2553) Standard frameless infill — 10–15 mm depending on span and fixity.
Laminated glass Overhead, coastal hotel and curved glass railing panels where residual strength is specified.
Hardware SS304 inland; SS316 pool, coastal and humid plant decks.
Edge finish Polished edges for shoe and spigot contact; CNC holes per shop drawing only.
Curved glass railing Heat-formed or faceted layouts from template survey — curved glass railing cost follows radius, height and lamination tier on BOQ.
System Comparison

Frameless vs Channel System Glass Railings

Criteria Frameless U channel / base shoe
Fixing Point spigot or shallow base shoe Continuous U channel or structural base shoe
Typical use Balconies, atria, feature stairs Podium parapet, long terrace runs
Maintenance Panel replacement by mark number Silicone and channel inspection cycles on exterior glass
Cross-reference This page Channel system glass railings
PMC / Consultant

Consultant and PMC Specification Checklist

  1. Architectural typical sections — guard height NBC 2016, handrail continuity at stairs.
  2. Glass make-up on schedule — toughened monolithic vs laminated, thickness tied to IS 875 load.
  3. Structural approval on spigot pull-out or base shoe anchors where required.
  4. Fixing system named on drawing — no substitution between spigot and channel without revision.
  5. Inspection: factory dimension check, site level survey, torque log for exposed fasteners.
Procurement

Procurement and Tender Considerations

Frameless glass railing installation companies on EPC tenders should confirm whether scope includes only supply or supply-and-fix. Sun Railings manufactures glass railing systems at commercial railing fabrication capacity with material approval packs for PMC filing.

  • Separate straight and curved modules on BOQ.
  • Material approval lead time before bulk glass cutting.
  • Factory inspection optional before first tower dispatch.
  • Phased dispatch to match façade access and hoist availability.

Architectural railing systems references for hospitality and IT campus work.

Buyer Questions

Commercial Buyer Questions — Frameless Glass Railing

What drives frameless glass railing cost on a tower BOQ?

Glass thickness tier, hardware grade, panel height and corner versus straight ratio — curved units priced on separate lines.

Is frameless glass railing suitable for exterior balcony conditions?

Yes when guard calculation, drainage at shoe and SS316 zones are on the approved detail — coastal projects step hardware grade on elevation map.

How does frameless compare to stainless steel glass railing on the same building?

Frameless on sell faces; stainless steel glass railings on service terraces — different shop drawing registers.

What submittals are needed for glass railing brands in India comparisons?

Material certificates IS 2553, sample panels, typical detail PDF and factory capability statement — not marketing brochures.

Can aluminium profile glass replace frameless on upper floors?

Aluminium glass railing is often specified on inland upper phases while frameless remains on podium and feature levels.

What site condition must be met before base shoe installation?

Finished screed level and edge tile complete — glass modules are not field-trimmed to absorb slab tolerance.

How are glass railing installation companies coordinated on design-build tenders?

Nominated supplier issues IFC shop drawings; main contractor holds set-out and access — interface meeting before first balcony pour above podium.

What wind-load documentation is required on high-rise frameless balconies?

IS 875 guard load category and corner-unit glass thickness sign-off on structural or architectural guard sheet before bulk order.

Frequently Asked Questions

Frameless Glass Railing Hyderabad — Common Questions

What is frameless glass railing?
Frameless glass railing is a guard system with no visible vertical posts — toughened safety glass (IS 2553) or toughened laminated glass (IS 16613) retained in a continuous base channel, base shoe profile, or SS316 spigot fixing. SR-FG-01 is Sun Railings frameless glass railing line. See SR-FG-01 frameless glass railing.
What is the difference between frameless and seamless glass railing?
Frameless and seamless describe the same system category — minimal-post glass guards with continuous glass spans and channel or spigot fixings only. Architects and PMC teams use both terms for SR-FG-01 specification on atriums, podiums, and premium lobbies.
What glass thickness for frameless glass railing?
12–15 mm toughened glass (IS 2553) is typical for frameless glass railing on podiums and balcony edges. Laminated toughened (IS 16613, e.g. 13.5 mm + 1.52 PVB) is specified in hospital, airport, and public assembly zones where post-breakage retention is required.
Frameless vs semi-frameless glass railing?
Frameless (SR-FG-01) has no visible vertical posts — glass retained in base channel, base shoe, or spigot only. Semi-frameless uses minimal top rail or intermittent balustrades while maintaining predominantly glass guard aesthetics. Compare SR-SG-01 SS balustrade-and-glass for visible balustrade frameworks.
Is frameless glass railing safe for commercial stairs?
Yes — frameless glass railing is safe for commercial stairs when designed to IS 875/NBC 2016 with correct base fixing, anchor type, edge distance, and torque specification for spigots. SR-FG-01 includes load documentation, glass make-up schedule, and SS316 hardware MTCs for PMC approval.
What is SR-FG-01 frameless glass railing?
SR-FG-01 is Sun Railings frameless toughened glass balustrade system using patch fittings or base-shoe channels with minimal visible metal — specified for premium lobbies, podiums and balcony guards across Hyderabad commercial projects.
What glass specification applies to SR-FG-01 frameless railing?
Panels are heat-soak tested toughened glass per IS 2553, typically 12–15 mm thickness based on span, fixing type and IS 875 guard load requirements on consultant structural notes.
Can SR-FG-01 frameless glass railing meet NBC 2016 guard height on commercial podiums?
Yes. SR-FG-01 packages are detailed to NBC 2016 Part 4 guard heights — typically 1.1 m for commercial circulation — with base-shoe or patch-fitting assemblies confirmed on architectural guard drawings.
What is the difference between SR-FG-01 and SR-SG-01 glass railing?
SR-FG-01 is frameless with patch or base-shoe fixings for minimal metal visibility. SR-SG-01 uses SS balustrades and top rails with glass infill — preferred where post-and-rail aesthetics or higher robustness is required on builder packages.
Does Sun Railings supply SR-FG-01 BOQ pricing for architect tender packages?
Yes. BOQ proposals include glass area schedules, fitting counts, channel lengths and installation allowances per metre of guard for PMC and consultant tender reconciliation.
What commercial applications suit SR-FG-01 frameless glass railing?
IT park lobbies, hotel atriums, mall podiums, residential tower balconies and institutional entrance guards — see project references including Microsoft Hyderabad and Hyderabad Metro concourse packages.
What maintenance is required for SR-FG-01 frameless glass railing?
Periodic glass cleaning, inspection of patch bolts and base-shoe set screws, and sealant checks at channel interfaces — maintenance schedules are included in handover documentation for facility teams.
What glass specification is standard for frameless glass railing in Hyderabad?
10mm and 12mm IS 2553 toughened safety glass are specified for commercial podium and atrium guards up to NBC 2016 height limits. Laminated toughened glass with 1.52mm PVB interlayer is used in assembly zones, airports and high-rise edges where post-breakage retention is required. Glass make-up is confirmed against IS 875 Part 2 horizontal load calculations in the structural consultant’s drawings.
What fixing systems are available for commercial frameless glass railing?
Sun Railings supplies three primary fixing methods: patch fittings (point-fixed standoffs), spider fittings (multi-arm structural connectors for large panels) and continuous channel base profiles (U-channel or base shoe on slab edge). Channel base is preferred for high-traffic commercial edges; patch and spider fittings suit feature zones where minimal visible hardware is required.
Which project types use frameless glass railing systems in Hyderabad?
Frameless glass railing Hyderabad installations include shopping malls and retail atriums, airport and metro concourses, SEZ and IT park circulation decks, hospital and institutional lobbies, and high-rise commercial podium edges. Systems are specified by PMC teams, architects and EPC contractors where unobstructed sightlines and documented IS compliance are required.
What is the difference between frameless and framed glass railing?
Frameless systems rely on glass panel strength and base or point fixings with no intermediate vertical posts — maximum transparency for atriums and facades. Framed systems use SS304 or SS316 balustrades and handrails with glass infill — higher redundancy for heavy assembly loads and simpler maintenance on industrial circulation routes. Selection depends on load path, maintenance access and consultant specification.
Does Sun Railings supply structural documentation for frameless glass railing submittals?
Yes. Each commercial frameless glass railing Hyderabad project includes glass make-up schedules, fixing method statements, IS 875 load references and material test certificates for PMC and authority submittals. Shop drawings are issued against approved architectural and structural drawings from our Jeedimetla fabrication facility.
Why Choose Us

What Sets Sun Railings Apart

Factory at Jeedimetla since 1998
Direct from our own manufacturing plant. No dealers, no middlemen. Full quality control from raw material to installation.

IS 875, IS 2553, NBC 2016 Compliant
All systems meet Indian Standards. Material test certificates and mill certs supplied with every order. Trusted by airports, metro systems and IITs.

Drawing-based Contracts
We quote Drawing-based contracts with no surprise escalations. Your budget is protected from material price changes throughout the project.

24-Hour Site Visit
Our engineer visits your site within 24 hours anywhere in Hyderabad for measurement, specification and a no-obligation quote.

On-Time Delivery
500+ projects delivered on schedule. Time-critical work completed at GMR Airport, Bhogapuram Airport, AIIMS Guntur and IIT Hyderabad.

Custom Fabrication
Curved handrails, non-standard heights, special finishes and bespoke configurations. Send us drawings and we fabricate to specification.

For non-linear sightline requirements on podium and atrium edges, see curved glass railing with factory-bent IS 2553 toughened glass.

Planning a Glass Railing Project?

IS 2553 toughened glass systems. SS316 spigot or base-channel. Free site visit within 24 hours. Drawing-based contracts. Factory at Jeedimetla, Hyderabad.

Plot 36, Road 80, Jeedimetla Industrial Estate, Hyderabad 500055
Request Consultation

For commercial, institutional or infrastructure glass railing projects